The reason why the climatic chamber cannot be humidified normally

KENTON Apparatus LTD. is a manufacturer specializing in the production of climatic chambers and has been rooted in this industry for 23 years, we sincerely entertain our guests and produce cost-effective products. The climatic chamber is widely used in biological tissue, cell culture, seed germination, plant cultivation, small animal and insect rearing.
How does the climatic chamber humidifier work?
Place the humidifier on the right rear of the artificial climate box, then insert the outlet pipe into the production pipe, and use ф20×1 soft plastic pipe to keep the humidifier outlet pipe and the climate box inlet pipe >3°elevation, avoid the plastic pipe sagging or flat , so as not to block the road with water. Therefore, the position of the humidifier can be appropriately moved and the thick plastic pipe of the outlet pipe can be rotated.
How is the climatic chamber humidifier connected to the electrical?
Insert the electrical plug of the humidifier into the socket on the lower rear right side of the climate box. The power supply to the humidifier is controlled by the climate box to ensure humidification. Generally speaking, the artificial climate box can realize functions such as heating and humidification under normal working conditions, if the humidifier is completed.

The climatic chamber cannot be humidified normally? Does it mean the humidifier is broken?
First of all, check whether the climatic chamber can be humidified normally. Generally, it can be seen from the humidification indicator of the artificial climate chamber, but the indicator light is on, which does not mean normal humidification, so it is necessary to analyze the situation. The first situation is that there is no fog and steam when the humidification indicator of the artificial climate box is on, and it is necessary to judge whether the humidifier itself is faulty; the second situation is that the humidification indicator of the artificial climate box is not good, there is no fog, it is very likely that the fuse is broken and needs to be replaced in time ;The third situation is that the humidification indicator of the artificial climate chamber is on, but the fog is not windy, that is, the fog is very weak, and the most likely cause is the fan failure; the last situation is that the humidification indicator of the climatic chamber is on, but there is wind and no fog , it may be the fouling of the transducer, which must be cleaned with a soft hand brush. In addition, it should be noted that other reasons can also cause the artificial climate box to not be humidified normally, such as water shortage in the water tank. Therefore, in order to avoid the abnormal humidification of the climatic chamber caused by this situation, it is necessary to check whether the water is sufficient before opening the artificial climate chamber. Of course, the climatic chamber cannot be humidified normally to ensure that the climatic chamber cannot be humidified normally. For example, the water tank is short of water. Therefore, in order to prevent the climatic chamber from being unable to humidify normally due to this situation, it is necessary to check whether the water is sufficient before opening the climatic chamber.